This image was saved from this machine with hard drive S.M.A.R.T. info at 2024-0605-0922: *****************************************************. For the drive: /dev/sda smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.8.0-11-generic] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: IND-S3MP/64G Serial Number: 201912070156 LU WWN Device Id: 0 000000 000000000 Firmware Version: SBFC21.2 User Capacity: 64,023,257,088 bytes [64.0 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: mSATA TRIM Command: Available Device is: Not in smartctl database 7.3/5528 ATA Version is: ACS-4 (minor revision not indicated) SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Wed Jun 5 09:22:18 2024 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (65535) seconds. Offline data collection capabilities: (0x79) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 30) minutes. Conveyance self-test routine recommended polling time: ( 6) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0 5 Reallocated_Sector_Ct 0x0013 100 100 050 Pre-fail Always - 0 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 81 12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always - 28 161 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 115 163 Unknown_Attribute 0x0003 100 100 050 Pre-fail Always - 43 165 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 5 166 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0 167 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 3 172 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 0 173 Unknown_Attribute 0x0022 100 100 000 Old_age Always - 0 192 Power-Off_Retract_Count 0x0012 100 100 000 Old_age Always - 23 194 Temperature_Celsius 0x0023 064 064 000 Pre-fail Always - 36 (Min/Max 33/36) 196 Reallocated_Event_Count 0x0000 100 100 000 Old_age Offline - 0 198 Offline_Uncorrectable 0x0012 100 100 000 Old_age Always - 0 199 UDMA_CRC_Error_Count 0x000b 100 100 050 Pre-fail Always - 0 241 Total_LBAs_Written 0x0012 100 100 000 Old_age Always - 118 242 Total_LBAs_Read 0x0012 100 100 000 Old_age Always - 72 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. The above only provides legacy SMART information - try 'smartctl -x' for more